Filtering escape hood or oxygen self-rescuer? Why oxygen deficiency determines the choice

The answer determines the required principle of protection. Only then design, handling and duration can be meaningfully compared.


The appropriate version also depends on the contaminant hazards and concentrations, escape conditions, physical demands and required operating time.

A filtering escape hood can remove certain contaminants from the ambient air. It cannot replace missing oxygen. If oxygen deficiency may occur along your escape route, you need a suitable escape apparatus that operates independently of the ambient atmosphere. Oxygen self-rescuers provide oxygen from a supply carried within the apparatus. 

What a filtering escape hood can do – and where its limitations lie 

Filtering escape hoods use ambient air. During inhalation, this air passes through a filter designed for specific contaminants. The gases, vapours or particles it can retain depend on the device version and its limitations of use. Depending on the version, the devices do not guarantee protection in oxygen-deficient atmospheres. Protection against carbon monoxide is also not provided by every version. The term ‘escape hood’ alone therefore does not indicate comprehensive protection. 

Filtering contaminants does not replace an oxygen supply 

You need to answer two questions separately when selecting a device:

  • Can the device deal with the contaminants that may occur, within its limitations of use?
  • Is there sufficient oxygen in the ambient air for it to be used?

The German Social Accident Insurance (DGUV) generally specifies at least 17 per cent oxygen by volume for filtering devices, and at least 19 per cent by volume for CO filters and certain areas. This does not constitute blanket approval for any filtering escape hood. Device-specific requirements and other conditions of use must also be met. 

A filter that covers a broader range of contaminants does not eliminate dependence on oxygen in the ambient atmosphere. This is precisely the limitation of protection by filtration. 

How oxygen self-rescuers operate independently of the ambient air 

Chemical oxygen self-rescuers have a closed breathing circuit. The exhaled gas is regenerated within this circuit and made available for breathing again. 

In devices with chemically bound oxygen, a regeneration cartridge performs essential functions: it binds carbon dioxide and moisture from the exhaled air and releases oxygen. A breathing bag receives the regenerated breathing gas. The oxygen supply therefore comes from the device itself.

The Dezega CARBO 30 illustrates this process. According to the manufacturer's instructions for use, the breathing gas flows through the regeneration cartridge during exhalation and inhalation. Carbon dioxide is removed and oxygen is added in the process. The chemical reaction generates heat; warming of the device and the inhaled gas is therefore part of normal operation. 

The key advantage: its own oxygen source

Independence from the ambient air addresses a specific hazard: breathing gas can still be supplied when the surrounding atmosphere contains insufficient oxygen and / or excessively high contaminant concentrations. 

German DGUV Rule 112-190 accordingly distinguishes between filter self-rescuers that depend on the ambient atmosphere and devices that operate independently of it with their own breathing air supply. Depending on their design and intended purpose, the latter can also provide protection in oxygen-deficient atmospheres and at high contaminant concentrations. 

For your device selection, this means: if the risk assessment identifies oxygen deficiency and / or excessively high contaminant concentrations in a potential escape scenario, the solution must cover this hazard. Higher filtration performance does not solve this problem. 

However, an independent oxygen source does not remove the restriction on operating time or the device's limitations of use. The facepiece must also be used correctly. The principle of protection is therefore an essential prerequisite; selecting a specific device requires further information about its use. 

Why even an oxygen self-rescuer has a limited duration 

The chemical oxygen supply in the device is limited. How long it lasts depends, among other factors, on physical exertion. The German Social Accident Insurance Institution for the Raw Materials and Chemical Industry (BG RCI) explains that chemical oxygen self-rescuers achieve longer durations at low workloads than during strenuous physical exertion. 

A rated operating time is therefore not a personal guarantee of operating time. In the CARBO instructions, for example, DEZEGA points out that running increases oxygen consumption and can shorten the operating time.

You should therefore consider the stated number of minutes together with the test conditions specified in the standards and your workplace escape scenario. The question is: how long does the group of people concerned need to reach a safe, contaminant-free area under the assumed conditions? 

Which questions determine the choice in tunnelling and mining ?

The German Social Accident Insurance Institution for the Building Trade (BG BAU) places oxygen self-rescuers within a comprehensive fire protection, escape and rescue plan. This includes escape routes, refuge chambers, communication systems and the organisation of rescue personnel, among other elements. The device is one component of this emergency preparedness. 

For selection, the German Social Accident Insurance Institution for the Raw Materials and Chemical Industry (BG RCI) lists potential contaminants and their concentrations, oxygen deficiency, thermal effects, and the nature and length of the escape route. 

The following comparison helps to put the principles of protection into context:

The table describes the operating principles. It does not replace a risk assessment or application-specific selection. 

„Our escape route is short. Is a filtering escape hood sufficient?“ 

A short route is relevant to escape planning. However, it does not change the fact that a filtering device cannot compensate for oxygen deficiency. You should therefore first check whether the principle of protection covers the potential atmosphere, and then determine the required duration (operating time). 

A simple calculation based on walking speed and device duration is also insufficient. In connection with the German Tunnelling Committee (DAUB), the German Social Accident Insurance Institution for the Building Trade (BG BAU) explains that escape route lengths must be limited with regard to device operating time and that planning assumptions must be checked on a case-by-case basis. 

For mining, the relevant area-specific requirements must also be observed. For operations within the scope of the German Federal Mining Act, the German DGUV Rule 112-190 indicates that their own regulations take precedence where such regulations exist. 

DEZEGA EmSCAPE and CARBO: an independent oxygen supply in different versions 

EmSCAPE, CARBO 30 and CARBO 60 use chemical oxygen and a closed breathing circuit. Differences include the facepiece and the stated operating durations. 

EmSCAPE: an escape hood with a chemical oxygen supply 

DEZEGA EmSCAPE combines a hood with an integrated half mask and its own chemical oxygen supply. The manufacturer describes the device as intended for escape from hazardous atmospheres, including oxygen-deficient atmospheres, and for protection of the respiratory tract and eyes. 

EmSCAPE thus illustrates an important distinction: a hood is one type of facepiece. Whether the device filters air or operates independently of the ambient air is determined by its breathing gas supply. 

Operating durations must be matched precisely to the relevant conditions. At a breathing minute volume of 35 l/min, the EmSCAPE instructions for use specify: 

  • at least 30 minutes according to ISO 23269-1;
  • at least 15 minutes according to EN 13794:2002.

These figures must not be combined into an unconditional "30-minute escape time".

For a specific underground application, the intended version and the operational requirements must be checked separately for compatibility. An independent oxygen supply alone does not constitute approval for every application.

CARBO 30 and CARBO 60: oxygen self-rescuers with a mouthpiece and nose clip 

The CARBO devices use a mouthpiece and a nose clip. The manufacturer's instructions for use describe how to use them; DEZEGA also offers corresponding training device versions. 

DEZEGA specifies the following values for the nominal rated operating time:

These figures do not represent a guaranteed individual escape duration. 

Further questions therefore arise when making your selection: what operating time do you need? How is the device to be carried? How can its handling be integrated into operational training? 

The DEZEGA product overview from BartelsRieger gives you access to the devices available. You can request advice to check their suitability for your application. 

What you should clarify before selecting a device 

Structured preparation makes the consultation more specific. Compile the following information where possible: 

  • Application: Where do the people work who need to be evacuated, and which areas must they leave? • Potential atmosphere: Which contaminants and concentrations need to be considered? Could oxygen deficiency occur?
  • Escape route: What distances, gradients and obstacles are involved? Which safe area should be reached?
  • Time required and exertion: What escape time is assumed, and under what conditions was it determined?
  • People involved: How many employees, visitors and contractors' personnel must be included in the evacuation plan?
  • Provision: Are devices to be carried on the person or kept ready at designated, accessible locations?
  • Existing organisation: What devices, exercises, inspection procedures and responsibilities are already in place?

This checklist is intended to prepare for the consultation. Technical selection must be based on your risk assessment and the workplace escape and rescue plan. 

„We already have filtering escape hoods.“ 

In that case, it is worth checking the existing equipment against its intended use. Have the manufacturer, device type and corresponding instructions for use ready for the consultation. 

The decisive question is whether the documented limitations of use match the potential escape conditions. The number of devices available answers this question no more than the general term "escape hood" does.

„An oxygen self-rescuer involves additional effort and expense.“ 

Purchase costs and operational effort belong in the procurement decision. In addition to device selection, ask for an explanation of the provision, checks, servicing and training required for the intended version. 

Request a quotation tailored to your needs. This will enable you to assess the effort and expense without comparing devices solely on the basis of their purchase price or a single stated duration in minutes. 

„Users must know exactly how to operate the device in an emergency.“

Clear handling that is as intuitive as possible is important. Equally important is preparation for the device actually used. The German DGUV Rule 112-190 "Use of respiratory protective devices" and the CARBO instructions for use provide for training and refer to training devices. Practical exercises should therefore be considered at the device selection stage. 

Also observe the intended purpose: escape apparatus are not apparatus for work or rescue. Brief supporting actions during escape must be distinguished from a planned entry into the hazardous area / danger zone. 

Selecting escape respiratory protection with BartelsRieger 

BartelsRieger supports you with product selection, training, inspection and technical support for DEZEGA respiratory protective devices. 

If you are reviewing existing escape apparatus or planning new equipment, please describe, where possible, the application, potential atmosphere, escape route or planned escape time, number of people and existing equipment in your enquiry. This provides the basis for a focused consultation. 